Pat Testing Record Template

  1. Pat Testing Record Sheet Template
  2. Pat Testing Record Form
  3. Pat Test Record Sheet Pdf Download
  4. Printable Pat Testing Record Sheet Free
  5. Pat Testing Record Sheet Pdf

Companies aren’t obliged to maintain detailed records of the devices they have had PAT tested. Nevertheless, it is a very good idea that you do. By keeping records, you can see which of your electrical devices is due for a PAT Test, ensuring you meet obligations to keep staff and occupants safe. PAT Testing is also easier when there’s a definitive list of equipment to refer to, so it’s worth retaining records for next time around.

5th Edition Risk Assessment Template. To help duty holders get to grips with the new 5th edition requirements for risk assessment Seaward have created a template for you to use and adapt. This template allows you to carry out PAT risk assessments to comply with the 5th Edition requirements. (Please be aware Seaward do not provide technical support for this template). PORTABLE APPLIANCE TESTING (PAT) REPORT/CERTIFICATE. Original Certificate DETAILS OF CLIENT/LANDLORD Client/ Address: Certificate reference. TEST EQUIPMENT DETAILS Test Equipment used Tested by Date Fuse rating (A) Serial Number Retest Date. Voltage (V) Rating (A) Insulation resistance 20M. Earth continuity.

PAT Testing Paperwork Whilst PAT Testing (Portable Appliance Testing) isn’t a legal requirement, you do have a legal responsibility to ensure your premises are safe for your staff, visitors and customers. If you choose to carry out PAT Testing, or have it completed by an external company (PAT company, electrician etc), it is good practice to record the results – whether good or bad – to. PAT stands for Portable appliance testing. It is the process of examining the safety of what is known as portable electrical appliances to detect faulty electrical equipment so they can be fixed to prevent any accident. Electrical appliances are considered 'portable' when there is a lead attached to them and connected to a plug. A typical PAT testing will include a visual inspection to ensure the electrical.

If your records have been lost, any competent PAT Testing company will provide you will their new records as proof that they have performed the necessary tests on your equipment. Such records will typically list each device that has been tested, its location, its class, and how it performs in each of the main parts of the PAT test: the visual inspection, the earth and insulation tests, and the functional check. Finally, the date that the device should next be tested will be given.

Legally, you don’t need to have a PAT Test certificate for every device that has passed. However, these certificates are issued routinely by PAT Testers, so it helps if you retain them. By having a PAT Testing certificate for a device, it proves that the device has been certified as safe to use, and therefore acts as a back up to prove that a company is in compliance with testing regulations. If someone takes you to court in future, you’ll be glad you have the paperwork to prove you’ve done everything you had to do to be safe.

Electricians carrying out PAT Tests may have carried out a formal training course with NICEIC or a similar provider. As part of their training, a PAT Tester will always learn how to issue PAT Testing certificates. Make sure you obtain yours once the tests are complete.

You can see some examples of PAT testing records here.

There are many common myths about portable appliance testing (PAT) - find out the key facts about the inspection and testing of portable electrical equipment here.

What is portable appliance testing?

Portable appliance testing (PAT) is the term used to describe the examination of electrical appliances and equipment to ensure they are safe to use. Most electrical safety defects can be found by visual examination but some types of defect can only be found by testing. However, it is essential to understand that visual examination is an essential part of the process because some types of electrical safety defect can't be detected by testing alone.

A relatively brief user check (based upon simple training and perhaps assisted by the use of a brief checklist) can be a very useful part of any electrical maintenance regime. However, more formal visual inspection and testing by a competent person may also be required at appropriate intervals, depending upon the type of equipment and the environment in which it is used

Record

I've been told that, by law, I must have my portable electrical appliances tested every year. Is this correct?

The Electricity at Work Regulations 1989 require that any electrical equipment that has the potential to cause injury is maintained in a safe condition. However, the Regulations do not specify what needs to be done, by whom or how frequently (ie they don't make inspection or testing of electrical appliances a legal requirement, nor do they make it a legal requirement to undertake this annually).

How frequently do I need to test my electrical appliances?

The frequency of inspection and testing depends upon the type of equipment and the environment it is used in. For example, a power tool used on a construction site should be examined more frequently than a lamp in a hotel bedroom. For guidance on suggested frequencies of inspection and testing, see: Maintaining portable and transportable electrical equipment.

Do I need to keep records of testing and should I label any appliances tested?

There is no legal requirement to label equipment that has been inspected or tested, nor is there a requirement to keep records of these activities. However, a record and / or labelling can be a useful management tool for monitoring and reviewing the effectiveness of the maintenance scheme – and to demonstrate that a scheme exists.

Do I need to test new equipment?

New equipment should be supplied in a safe condition and not require a formal portable appliance inspection or test. However, a simple visual check is recommended to verify the item is not damaged.

I have been told that I have to get an electrician to do portable appliance testing work. Is that correct?

The person doing testing work needs to competent to do it. In many low-risk environments, a sensible (competent) member of staff can undertake visual inspections if they have enough knowledge and training. However, when undertaking combined inspection and testing, a greater level of knowledge and experience is needed, and the person will need:

  • the right equipment to do the tests
  • the ability to use this test equipment properly
  • the ability to properly understand the test results

Where can I get more information about maintaining portable appliances used in different environments?

Pat Testing Record Sheet Template

Information is also available in: Work using electrically powered equipment.

I run a tool hire business? What do I need to do and are there additional responsibilities for the person hiring my tools?

It is strongly recommended that equipment suppliers formally inspect and test the equipment before each hire, in order to ensure it is safe to use. The person hiring the equipment should also take appropriate steps to ensure it remains safe to use throughout the hire period. The question 'What is portable appliance testing?' above gives guidance on what this will entail.

Are there are any case studies about portable appliance testing?

A high street travel agent's approach to PAT

A high street travel agency thought about what it needed to do to maintain its portable electrical equipment. As their work generally included office work and dealing with customers the manager considered that health and safety risks would be generally low. The portable electrical equipment was used in a clean and dry shop by a small number of employees. In deciding what action was needed:

  • the manager thought about the type of portable equipment that was used in their shop and the level of risk that it might create;
  • she looked for electrical equipment in the shop and found that there were a number of computers, a fax, two printers and a vacuum cleaner;
  • she then thought about the likelihood that the items could become damaged:
    • Computers, printers and faxes were not moved around much and were positioned so that the cables could not become trapped, so the probability that items might be damaged was extremely low. The manager decided that they would be maintained by a visual inspection every 5 years.
    • The vacuum cleaner was heavily used. The manager remembered that the cable was repaired 6 months ago by an electrician as it had been pulled out of the cable grip, so she knew that in future it would need to be looked at more often. It was decided that the vacuum should have a visual inspection every 6 months and that employees would be encouraged to look for signs of damage to the plug and cable before plugging it in.
  • The manager kept a note of the checks in her diary to remind herself to re-inspect the equipment.
  • Only the vacuum cleaner was thought to present a high risk, so the manager decided to get this tested after twelve months and review this after 24 months.
  • None of the remaining equipment in use was thought to present a high risk, so the manager decided that full portable appliance testing was not needed for these items.

Key Points:

  • Portable electrical equipment must be maintained to prevent danger.
  • For most portable electrical equipment in a low-risk workplace, a portable appliance test is not needed.
  • Working out what you have to do is not time consuming or complicated.
  • Simply looking for signs of damage is a good way of Maintaining portable electric equipment.

Pat Testing Record Form

HSE's approach to maintaining portable appliances in its own offices

Pat Test Record Sheet Pdf Download

In 2011, the HSE reviewed its approach to portable appliance maintenance in its own offices. Thinking about the type of equipment in use, and how it was used, the HSE looked back at the results from its annual testing of portable appliances across its estate over the last five years. Using the results of the previous tests, the HSE decided that further portable appliance tests are not needed within the foreseeable future or at all for certain types of portable equipment. Also, they decided to continue to monitor any faults reported as a result of user checks and visual inspections and review its maintenance system if evidence suggests that it needs revising. Electrical equipment will continue to be maintained by a series of user checks and visual inspections by staff that have had some training.

Printable Pat Testing Record Sheet Free

Key Points:

  • Annual portable appliance testing is not always necessary in low risk environments
  • You do not need to be an electrician to carry out visual inspections
  • Low cost user checks and visual inspections are a good method of Maintaining portable electric equipment

Is Portable Appliance Testing (PAT) compulsory?

No. The law simply requires an employer to ensure that their electrical equipment is maintained in order to prevent danger. It does not say how this should be done or how often. Employers should take a risk-based approach, considering the type of equipment and what it is being used for. If it is used regularly and moved a lot eg a floor cleaner or a kettle, testing (along with visual checks) can be an important part of an effective maintenance regime giving employers confidence that they are doing what is necessary to help them meet their legal duties. HSE provides guidance on how to maintain equipment including the use of PAT.

Resources

Pat Testing Record Sheet Pdf

See also

Related content

  • ESQCR incidents